Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13684727

- Product Categories
- Friendly Links
Information Name: | Initial start Qingyang acoustic tube Notes 15733750102 |
Published: | 2015-04-01 |
Validity: | 30 |
Specifications: | Qingyang acoustic tube |
Quantity: | 100000000.00 |
Price Description: | |
Detailed Product Description: | When you first start Qingyang acoustic tube Notes 15,733,750,102 an initial start low temperature hot water floor radiant heating (ie water Qingyang acoustic tube), to operate in accordance with the following procedure: first pass into the 25-30 ° C water, open floor water return valve between the pipe and the pipe, so that the water supply pipe backwater into the floor, a week after the operation, weekly water temperature 5-10 ° C, until the water temperature reaches 60-65 ° C, the only normal operation . When using water Qingyang acoustic tube system for maximum temperature 65 ℃, should not exceed 60 ℃. Such as water temperature exceeds 60 ° C, the valve should be opened between the backwater and water, so the water floor heating return water for use. To adjust the room temperature, should be based on outdoor air temperature, water temperature of the floor heating system and water entering the system can be adjusted. The outdoor temperature is high, the system can reduce the amount of water and reduce water temperature, and vice versa. During Qingyang acoustic tube system operation should be checked regularly filters, valves, thermometers, pressure gauges, etc. are normal use, in view of the effect of temperature and pressure pipes produced by the creep characteristics, during the heating, there should be someone to sub-catchment front-end device and the valves, fittings and tighten a few times, and regular cleaning of the filter impurities, if damaged, should overhaul before use. Second, before the start of the phenomenon, although the developers check for leaking or heating service provider in the acceptance houses have experience next time Qingyang acoustic tube system is qualified, but man that may arise during the renovation destruction http: //www.jcgxx .com /, will still affect the normal operation of Qingyang acoustic tube system. Prior to the installation of low temperature hot water radiant heating (referred to as "water Qingyang acoustic tube") of the family system, run the water for the first time in Qingyang acoustic tube systems to cope with pressure piping system test to see whether there is leaking, leakage leakage phenomenon. The reason for the pressure test conducted, the owners are worried about accidentally damaged during the renovation of the water Qingyang acoustic tube system. Third, start Qingyang acoustic tube can not sudden warming or whether it is the first time the use has been used for some time, the water pipes or electric acoustic Qingyang Qingyang acoustic tube, open Qingyang acoustic tube system, the system temperature can not be set too high. At lower indoor temperature, the sudden increase in temperature Qingyang acoustic tube system, Qingyang acoustic tube element for a time unable to accept the high temperature, there is no time to adapt to a slow transition, not only will damage Qingyang acoustic tube components of the system, thereby affecting the life of Qingyang acoustic tube system, and may make the floor deformed. Fourth, pay attention to the behavior start saving some people think, "turn off when you leave the room Qingyang acoustic tube system, and then back to the room when the acoustic tube system opens Qingyang" This approach can save energy, but in fact, this is a worth the candle, and easy to damage the Qingyang acoustic tube element approach. More economical approach may be this: When people leave, the indoor temperature controlled at 13 ℃ ~ 15 ℃, after returning home, the room temperature control to 18 ℃ ~ 20 ℃. With this setting, the room temperature rises faster, able to rise from 15 ℃ to usually within half an hour of the 18 ℃ ~ 20 ℃. Of course, in the house for a long time (more than three days) empty cases, you can consider closing Qingyang acoustic tube systems, and other home and then later turned Qingyang acoustic tube system. |
Admin>>>
You are the 5751 visitor
Copyright © GuangDong ICP No. 10089450, Cangzhou City, Mai Industrial Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 5751 visitor
Copyright © GuangDong ICP No. 10089450, Cangzhou City, Mai Industrial Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility